Positron Emission Tomography (PET) with 1-Aminocyclobutane-1- (11)C carboxylic Acid (1- (11)C -ACBC) for Detecting Recurrent Brain Tumors.
Author | |
---|---|
Abstract | :
This study was done to determine whether 1-[(11)C]ACBC PET has any advantages over 2-[(18)F]FDG PET, CT, or MRI in detecting recurrent brain tumors, and whether quantitative 1-[(11)C]ACBC PET information improves the accuracy of "visual" image interpretation.Twenty patients with recurrent brain tumor underwent dynamic PET. Images were analyzed by visual interpretation; in addition, standardized uptake values (SUVs) and Patlak values (k(1)*k(3)/k) were evaluated.1-[(11)C]ACBC identified 19/20 recurrent brain tumors, [18F]FDG 13/19, MRI 13/19, and CT 8/16. Based on SUVs, the average tumor-to-contralateral gray matter ratio of 1-[(11)C]ACBC was 5.0 and 0.5 for 2-[(18)F]FDG. Mean Patlak values of 1-[(11)C]ACBC were 0.044 +/- 0.047 for high and 0.034 +/- 0.026 for low grade tumors. However, visual interpretation was effective without quantitative PET data.1-[(11)C]ACBC, accurately detects recurrent tumors for selecting biopsy sites and treatment planning. |
Year of Publication | :
1998
|
Journal | :
Clinical positron imaging : official journal of the Institute for Clinical P.E.T
|
Volume | :
1
|
Issue | :
3
|
Number of Pages | :
165-173
|
ISSN Number | :
1095-0397
|
URL | :
https://linkinghub.elsevier.com/retrieve/pii/S1095039798000107
|
DOI | :
10.1016/s1095-0397(98)00010-7
|
Short Title | :
Clin Positron Imaging
|
Download citation |